μ5z (mu5z)

Stan Zurek, μ5z (mu5z), Encyclopedia Magnetica,
http://www.e-magnetica.pl/doku.php/mu5z

μ5z or mu5z - initial impedance permeability1) approximating value of initial magnetic permeability μi obtained by measuring the relative magnetic permeability at the excitation of magnetic field strength H = 5 mOe = 0.005 Oe ≈ 0.4 A/m.2)3)

Therefore for the same material, rather confusingly, the value of μ5z defined at H = 5 mOe is practically very close to μ4z defined at H = 4 mA/cm = 0.4 A/m, which itself is identical to μ0.4z (because it is defined at H = 0.4 A/m).

Illustration of several types of permeability, calculated as a ratio (slope) of change of B to change of H: μa or μampl - amplitude, μmax - maximum, μi - initial, μΔ - incremental, μrev - reversible
→ → →
Helpful page? Support us!
→ → →
PayPal
← ← ←
Help us with just $0.10 per month? Come on… ;-)
← ← ←

See also

References


3) Definition of μ5Z provided via email from nickel.alloys@aperam.com by H. GRUSON for the Pierre Chevanard research Center, {2016-01-11}
This website uses cookies. By using the website, you agree with storing cookies on your computer. Also you acknowledge that you have read and understand our Privacy Policy. If you do not agree leave the website.More information about cookies
mu5z.txt · Last modified: 2023/12/19 14:45 by stan_zurek

Except where otherwise noted, content on this wiki is licensed under the following license: CC Attribution-Share Alike 4.0 International
CC Attribution-Share Alike 4.0 International Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki
Legal disclaimer: Information provided here is only for educational purposes. Accuracy is not guaranteed or implied. In no event the providers can be held liable to any party for direct, indirect, special, incidental, or consequential damages arising out of the use of this data.

For information on the cookies used on this site refer to Privacy policy and Cookies.